Can a wind turbine vibration spectrum be accepted when the recorded signal clipped?

Small wind / Buyer questions

Mechanical and structural acceptance

Can a wind turbine vibration spectrum be accepted when the recorded signal clipped?

The short answer

A spectrum derived from a clipped recording can misrepresent the vibration that was present. Clipping loses information about the original waveform and can introduce features in the spectrum. Identify the affected channel and intervals, then decide whether the remaining evidence still covers the required acceptance states.

Look beyond the processed plot

Request the original time series, configured input range, sensor range and any instrument overload flags. Flat limits in the waveform can suggest clipping. A channel can also overload before the final digitized trace, so an absence of obvious flat tops does not establish that the whole chain stayed within range.

National Instruments distinguishes overload at different stages of dynamic signal acquisition. Its device guidance treats affected samples as unreliable and describes how a digitized trace can fail to expose some analog overload.

Keep derived results attached to their input intervals

A processed spectrum can blend corrupted and valid intervals. An overall result can also be biased if a short high-amplitude event is omitted without disclosure. Identify the exact windows used for each plot and keep excluded data visible in the test record.

Reprocessing can analyze unaffected windows if the agreed method still has sufficient coverage. It cannot recreate the missing peaks or original waveform from the saturated values alone.

Resolve the evidence gap before closing acceptance

Ask whether the unaffected record covers the required machine state, location, duration and vibration band. If overload occurred during the very event the test was meant to assess, the available result may leave that clause open. Agree any repeat under the approved test plan with the equipment and measurement specialists.

Sources

Examples are illustrative. Confirm product-specific performance, compatibility and supply scope in the applicable documents.