Small wind / Buyer questions
Resistor ratings and accuracy data
Do individual resistor limits establish network ratio tracking?
The short answer
Individual absolute resistance tolerance and TCR limits can support an engineer's conservative bound on ratio error or temperature tracking. That bound may satisfy the actual requirement. It does not establish a tighter supplier-specified relative limit. Vishay distinguishes individual element characteristics from relative tracking. Assess the required relationship and its conditions before deciding whether a calculated bound or dedicated network evidence is sufficient.
Specify the quantity used by the circuit
Identify whether acceptance concerns each element's resistance, a resistance ratio or the voltage division in the intended connection. Request the ratio reference, initial relative tolerance and temperature-tracking conditions. These terms need clear definitions in the offered specification. A network package alone does not establish the particular relative-performance limits required by the application.
Compare arrays using the relevant relationship
In a hypothetical wind-project measurement circuit, two arrays meet the same individual resistance and absolute TCR limits. One supplier also specifies ratio tolerance and tracking; the other provides only element limits. The engineer can compare a conservative bound derived from those limits with the circuit's requirement. A suitable bound may suffice; a tighter requirement may need additional relative-performance evidence. The absence of a dedicated supplier figure is not an automatic failure.
Preserve the conditions attached to relative performance
The accepted record should identify the elements being compared, the specified ratio and the applicable thermal and loading assumptions. Vishay's discussion also shows why unequal element heating and common lead contributions need appropriate interpretation. Do not assume a catalogue tracking figure covers every assembled connection or load pattern. Review any changed arrangement with the designer, keeping initial ratio tolerance, temperature tracking and long-term stability as separately documented characteristics.
Sources
- Vishay Precision Thin Film Technology (2010), ratio tolerance, tracking and stability
- Vishay Resistors 101 (2012), initial tolerance and coefficient terminology
Examples are illustrative. Confirm product-specific performance, compatibility and supply scope in the applicable documents.