Can upstream mechanical dewatering change the electricity a dryer can use from wind?

Small wind / Buyer questions

Application loads and feasibility

Can upstream mechanical dewatering change the electricity a dryer can use from wind?

The short answer

Yes. If an upstream process removes some water mechanically before heating, the dryer may have less water to evaporate. The press or centrifuge can also add electricity demand and change the timing or condition of the incoming material. Compare the complete intended process for the same acceptable finished output rather than reusing the dryer’s earlier electricity profile unchanged.

Draw the material and electrical boundaries

Identify the feed to the dewatering stage, the discharged water and any solids it carries, the feed to the dryer and the finished product. A U.S. Department of Energy study on food and beverage manufacturing discusses mechanical dewatering upstream of thermal drying as a possible energy opportunity. Its examples do not establish what will happen for this material or equipment. Record the delivered moisture and quality requirements in both cases.

Measure each stage during representative operation

Compare electricity and material records for the dewatering equipment, dryer, conveying and any added auxiliaries that lie inside the boundary. Dryer demand may decline while electricity rises earlier at the dewatering stage. The net result depends on the equipment, actual retained moisture and operating sequence. A change in production rate or rejected product can make two meter totals incomparable without further evidence.

Use the agreed future operating profile for wind

Provide the original process and approved alternative as separately labelled load cases. Preserve times, accepted throughput and any process limitations, and avoid assuming that all energy reductions will occur when wind would have supplied the dryer. If the new process has not been demonstrated, identify the assumptions and the validation needed from the owner. The proposed turbine contribution can then be compared with both the timing of electricity use and the service the plant must deliver.

Sources