Does a synchronized network interface prove a wind logger timestamps records with that clock?

Small wind / Buyer questions

Electrical diagnostics and service tests

Does a synchronized network interface prove a wind logger timestamps records with that clock?

The short answer

A network interface may have a PTP Hardware Clock while a logging application timestamps measurements from the operating system clock or another source. The Linux kernel documents distinct hardware and software timestamp sources, and LinuxPTP documents explicit synchronization between clocks. Hardware support or an interface lock indication does not by itself establish the origin or accuracy of the recorded timestamps. Check the data path and clock relationship together.

Find where the stored timestamp is assigned

Record the logger, application version, sensor acquisition path and each timestamp field. Distinguish a timestamp assigned at the measurement, at network arrival or when the application writes a record. In a hypothetical system the network interface is synchronized, while the application stamps each row using an operating system clock with no demonstrated link to it.

Verify the clock actually read by the application

Ask the integrator how the application obtains its time and which configuration transfers time between the interface and system clocks. Request a record of the accepted clock relationship and a controlled comparison against a relevant event. A capture of a hardware packet timestamp can confirm the packet observation point while leaving the timestamp of the underlying measurement unresolved.

Preserve the timestamp provenance

Save the clock source, creation point, synchronization path and applicable uncertainty with the data format. Retain software and driver versions for troubleshooting. If a hardware upgrade changes the available timestamp sources, verify the specific logging field again. This lets reviewers decide which observations can be compared across equipment without assuming that all recorded time came from the synchronized interface.

Sources

Examples are illustrative. Confirm product-specific performance, compatibility and supply scope in the applicable documents.