Can an acceptable LAeq close a wind-noise requirement for LAFmax?
The short answer
Only evidence for the requested quantity can close that requirement. LAeq describes an energy average, while LAFmax records the greatest A-weighted FAST sound level during the stated period. NTi Audio distinguishes these indicators and their time behavior. A satisfactory average does not establish the separately requested maximum, even when both figures come from the same instrument.
Name both quantities in the submission
Record the criterion’s complete parameter, frequency weighting and observation period alongside the parameter actually supplied. Ask whether the maximum was measured and retained during the same accepted operating case. A report field labelled maximum without the detector definition leaves an important part of the requested evidence unresolved. Keep the original instrument output available for the reviewer.
Review an average-only report
In a hypothetical site assessment, most of the measured period is steady but a brief event raises the detector output. The supplier submits only LAeq. The acoustic reviewer asks for the required LAFmax result and the interval or event information supporting its interpretation. The average alone cannot recreate a maximum that was not preserved in the available data.
Keep separate conclusions for separate criteria
Retain the accepted average and maximum results with their acquisition settings and applicable operating conditions. Identify any requirement still lacking evidence rather than treating one metric as a substitute. The responsible assessor must apply the project’s stated method to each quantity and decide whether further observations are needed. This record makes the scope of the acoustic submission clear without introducing a generic wind-noise limit or acceptance outcome.
Sources
Examples are illustrative. Confirm product-specific performance, compatibility and supply scope in the applicable documents.